RAFTEC 161H mixing unit (without pump)
Documentation
Passport |
The pump-mixing unit RAFTEC Warm Floor LSG-161H is intended for the creation of low-temperature heating systems (of the "warm floor" type). It is mounted on the collector group of the low-temperature circuit and connected to the high-temperature circuit of the heating system. Ensures constant circulation of the coolant in the circuit to achieve uniform heating of the floor and comfortable heating. The pumping-mixing unit performs the function of preparing the coolant of the required temperature and feeding it to the distribution manifold (comb). The pump-mixing unit is adapted for joint use with distribution collectors of underfloor heating loops with a center-to-center distance between collectors of 210 mm.
➠
|
Description
The pump-mixing unit is intended for use in heating systems with a coolant temperature reduced to a set value. The unit ensures maintenance of the set temperature and flow in the circulation circuit, and also allows to adjust the temperature and flow of the coolant depending on the user's requirements.
Specifications
Body material: | Brass |
Body seal material: | EPDM rubber |
Operating environment temperature, ° C: | up to 90 |